Sign In | Join Free | My gimpguru.org
China Guangdong ALI Testing Equipment Co,.Ltd logo
Guangdong ALI Testing Equipment Co,.Ltd
GSKA Group Specialized in kinds of PARTS since 1985, Developed and manufactured various generators and generator sets.
Active Member

13 Years

Home > Perkins Diesel Generator >

400KW 500KVA Perkins AC 3 Phase Diesel Generator Tank Fan Cooling

Guangdong ALI Testing Equipment Co,.Ltd
Contact Now

400KW 500KVA Perkins AC 3 Phase Diesel Generator Tank Fan Cooling

  • 1
  • 2

Brand Name : GSKA

Model Number : GSA-W36

CertifiCAT-partsion : CE SGS ROHS UL

Place of Origin : Donggaun,china

MOQ : 1set

Price : negotiate

Payment Terms : L/C, T/T

Supply Ability : 150 Set / Sets per Month

Delivery Time : 15-30working days after received deposit

Packaging Details : The outer packing is first packed with foam plastic, and then reinforced with strong wooden cases.

Warranty : 3 year

Frequency : 50HZ

Rated Voltage : 400/230V

Brand : GSKA

Speed : 1500/1800 RPM

Weight : 2700

Cooling Type : Tank Fan Cooling

Contact Now

400KW 500KVA Perkins AC 3 Phase Diesel Generator, Tank Fan Cooling

product presentation of diesel generator :

GSA series diesel generator sets adopt imported Perkins engines, and are equipped with famous and excellent generators such as Shanghai Kepu, Siemens, Stanford, etc. The product has a compact structure, small size, light weight, low fuel consumption, and convenient use and maintenance. The following are the features of GSA-W36 diesel generator:

1. Low noise and high emission standards: Meet the emission standard of 1/2ta luft.

2. High economy: Adopting four top cylinder valve structures to optimize airflow control, as well as perfect mist injection of fuel injectors, ensuring fast combustion, high efficiency, and economy.

3. Stability and reliability: Developed and tested using advanced multi-point injection cooling system to control piston temperature, as well as multi-element analysis control to ensure stability, low fuel consumption, and low wear. Perkins diesel engines are widely used in national defense, aviation, vehicles, ships, engineering machinery, and generator sets, and are recognized worldwide for their small size, light weight, strong resistance to sudden load, low noise, and economic reliability.

PERKINS Technical Parameters(220-550KW)
Genset
Model
GSA-W36
GSA-W37
GSA-W38
GSA-W39
Rated Power(KW/KVA)
220/275
240/300
280/350
320/400
Standby Power(KW/KVA)
242/303
264/330
310/388
350/438
Rated Current(A)
396
432
505
577
weight(kg)
2200
2700
Size(mm)
2800*1100*1800
3150*940*1910
3150*940*1970
Diesel
Engine
Model
1606A-E93TAG4
1506A-E88TAG5
2206C-E13TAG2
2206C-E13TAG3
Manufacturer
For PERKINS
Continuous Power(KW)
220
224
280
320
Standby Power(KW)
242
264
308
352
Number of Cylinders
6
Cylinder Diameter*Stroke(mm)
120*145
117*136
130*157
Cylinder Arrangement
In-line
Compression Ratio
/
Displacement(L)
10.6
8.7
12..5
Intake Type
Exhaust gas turbocharger
Cooling Type
Tank fan cooling
Rated Speed(rpm)
1500
Fuel Consumption(g/kwh)
≤198
Discharge Temperature(℃)
571
Unpitched Sound(db)
102
Speed Regulation
Electronic Speed Regulation
Alternator
Nominal Voltage(V)
400/230
Alternator(Optional)
Wandi, Stamford, Engga, Marathon, Elmaer, Leroy-Somer, etc.
Rated Capacity(KW/KVA)
220/275
240/300
280/350
320/400
Rated Power Factor
0.8(lag)
Exciter Type
Self Excitation Brushless
Maximum Voltage Adjustment Rate
±1%
Phase
AC Three Phase
Control
Panel
Control Cabinet Model
TBZK880
Controller(Optional)
SmartGen, Deepsea, Comap
Rated Capacity of Circuit Breaker(A)
400A
630A
Accumulator
Rated Capacity(AH)
2×120AH 12V
2×150AH 12V

400KW 500KVA Perkins AC 3 Phase Diesel Generator Tank Fan Cooling

400KW 500KVA Perkins AC 3 Phase Diesel Generator Tank Fan Cooling

FQA:

Q1:What is your MOQ of silent diesel generator? How long is your processing time for MOQ?

A:1 set. Within TWO working days or 48 hours...

Q2:Is the diesel generator customized?

A:Yes. Color, logo and packing can be customized according to customers design.... diesel generator

Q3:What is your company production capacity?

A:144 sets each day....

Q4:What is the delivery time for the diesel generator?

A:20 days after advance payment.If the items which you purchase is in stock we can send them out immediately....

Q5:How long is your warranty period for your diesel generator?

A:1 year or 1000 hours warranty whichever comes first except the wearing and tearing parts.We suggest customers buy some wearing and
tearing parts in each order....

Q6:What are your payment terms?

A:T/T 30% deposit, 70% balance should be paid against the B/L copy.D/P for regular good reputation customers. Paypal is accepted for one set,
but please discuss to our sales person first....

Q7:Is it alright to make customer's own brand name on the diesel generator?

A:Sure, as long as you authorize us to use your brand on your behalf.We have over 10 years OEM/ODM experience....

Product Tags:

Perkins 3 Phase Diesel Generator

      

400KW Perkins Diesel Generator

      
Quality 400KW 500KVA Perkins AC 3 Phase Diesel Generator Tank Fan Cooling wholesale

400KW 500KVA Perkins AC 3 Phase Diesel Generator Tank Fan Cooling Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangdong ALI Testing Equipment Co,.Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)